OTT RLS Non-Contact Radar Sensor

Dimensions:

– Length: 8.7 in.
– Width: 6.0 in.
– Height: 7.5 in.
– Weight: 4.6lbs.

Material:

Housing: ASA
(UV-stabilized ABS)
Front Plate: TFM PTFE

Protection:

IP 67

Measuring range:

2.6- 115 ft (0.8m - 35m)

Resolution:

0.01 ft (0.001m) SDI-12 Interface

Accuracy:

2.6 - 4.9 ft.: +/-0.03 ft.
4.9 - 98.4 ft.: +/-0.01 ft.
98.4 - 115 ft.: +/- 0.03 ft.

Temperature range:
(Operating temperature) 
-40 °F to 140 °F
-40 °C to +60 °C


Sensor technology:

Non-contact measurement of water level using impulse technology.

Transmitting frequency:  24 GHz (pulse radar)
Beam angle:  +/- 6°
Dead range:  2.6 ft. (0.8 m)
Horizontal clearance:  Min. 0.66 ft. (0.2 m), e.g. from a wall
Measuring interval:  20 sec. (320 values, creating mean values)

Power supply:

Nominal 12/24 V DC 9.6 ... 28 V DC

Power consumption:

Active: 12 mA @ 12 V DC
Stand-by: <50µA

Integrated lightning protection (standard):

To reduce the possibility of damage caused by over-voltage (lightning).

SDI-12 interface:

– Digital transmission up to 230 ft.
– Digital transmission up to 985, with separate voltage and point-to-point connection (no SDI-12 bus operation)

RS485 interface:

– Digital data transmission up to 3,300 ft (1,000 m) distance –Transmission rate 1,200 bps

Signal cable:

– SDI-12 interface: 20 AWG
– RS-485 interface: Cable lengths up to 1,650ft. use AWG 22. For cable lengths greater than
1,650 use AWG 20.

FCC ID: OA6OTTRLS

Hach Company Privacy Policy Site Map